Technical Parameters of Outdoor Prefabricated Substations

Feb 16, 2026

Leave a message

The operating conditions for outdoor prefabricated substations stipulate an altitude not exceeding 1000m, an ambient temperature range of -25°C to +40°C, a daily average relative humidity not exceeding 95%, and a monthly average not exceeding 90%. Furthermore, the installation site must be kept clear of fire sources, explosive hazards, conductive dust, chemically corrosive gases, and severe vibrations.

 

Its functional features include a "three-in-one" integrated design comprising high-voltage switchgear, transformers, and low-voltage switchgear. The system offers comprehensive high- and low-voltage protection, ensures safe and reliable operation, and requires minimal maintenance. It boasts a compact footprint, low investment cost, short production cycle, and ease of relocation. The enclosure utilizes a double-layer (composite panel) structure to facilitate thermal insulation, heat dissipation, ventilation, aesthetic appeal, and high-level environmental protection. A variety of enclosure materials are available, including stainless steel, aluminum alloy, cold-rolled steel, and color-coated steel. The high-voltage ring main unit can be equipped with a Feeder Terminal Unit (FTU) and features "four-remote" capabilities (telemetry, telecontrol, telesignaling, and teleadjustment) to enable reliable detection of short circuits and single-phase ground faults.

 

Regarding key configurations, the high-voltage side typically employs a load switch-fuse combination for protection; should a fuse in one phase blow, a three-phase trip mechanism is triggered. The load switch is available in various types-including compressed air, vacuum, and SF6 gas-and can be fitted with an electric operating mechanism. For transformers with a capacity exceeding 800kVA, a vacuum circuit breaker option is available for protection. On the low-voltage side, the main incoming switch utilizes a universal or intelligent circuit breaker to ensure selective protection, while the outgoing feeder switches employ new-generation molded-case circuit breakers. Additionally, the system can be configured with an intelligent, automatic reactive power compensation device, offering a choice between contactor-based and contactless switching methods.

 

Other critical parameters include rated capacity (typically measured in kVA or MVA), rated voltage (e.g., 10kV/0.4kV), short-circuit impedance, connection group (e.g., Y/Yno, D/Yno, etc.), insulation class, cooling method (e.g., natural cooling, air-forced cooling, or water cooling), and ingress protection (IP) rating (e.g., IP54, IP65, etc.).

Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!