Product Description
15kV Meta-Clad Switchgear is a medium voltage solution that can be custom engineered to fit all kinds of applications and safety requirements. You can put it together in different combinations depending on what you need it to do. People trust it for things like control and distribution, main main automatic transfer,main tie main automatic transfer, main service disconnect, switching, that kind of stuff.

Technical Parameters of VS1-24,VN2-24 Vacuum Circuit Breakers
|
Item |
Unit |
Parameter |
||
|
Rated Voltage |
kV |
24 |
||
|
Rated Insulation Level |
1 min Power Frequency Withstand Voltage (RMS ) |
60 |
||
|
Lightning Impulse Withstand Voltage (Peak ) |
125 |
|||
|
Rated Frequency |
Hz |
50/60 |
||
|
Rated Current |
A |
630,1250,1600,2000 |
630,1250,1600,2000,2500,3150 |
|
|
Rated Short-Circuit Breaking Current |
kA |
20 |
31.5 |
|
|
Rated Short-Circuit Making Current (Peak) |
50 |
80 |
||
|
Rated Short-Circuit Making Current (4s) |
20 |
31.5 |
||
|
Rated Peak Withstand Current |
50 |
80 |
||
|
Rated Single Capacitor Bank Breaking Current |
A |
630 |
||
|
Rated back-to-back capacitor bank breaking current |
400 |
|||
|
Number of Rated Short-Circuit Breaking Operations |
Times |
50 |
||
|
Mechanical Endurance |
20000 |
|||
|
Rated Operating Sequence |
O-0.3s-CO-180s-CO |
|||
Features and Advantages
Rear access for load and incoming connections;
Compartmentalized construction with breaker compartment for each device;
Automatic shutters that open and close with breaker racking position;
There are independent pressure relief channels with exhaust between the compartments of the main circuit system.
Application Scenario
Industrial Manufacturing
Data Centers
Utility Distribution Networks
Renewable Energy Integration
Frequently Asked Questions
Q1: Can this product be used in high-altitude areas?
A: This switchgear is designed for standard use at altitudes of 1000 meters and below.If your project site is higher than 1000 meters,its insulation and heat dissipation might be affected a bit.We suggest you let us know the on-site conditions in advance when selecting the model.We can then adjust the design specifically based on the actual altitude.
Q2: Is the 15kV Meta-Clad Switchgear okay for use in high-humidity environments?
A: With the standard design the relative humidity requirement is a daily average no more than ninety five percent and a monthly average no more than ninety percent.If your site is pretty humid and it stays above those levels for a long time the equipment could have issues with moisture affecting its stability.
Q3: How do you keep maintenance personnel safe when they are working on this equipment?
A: Safety is really built into the design from the start.We use things like five prevention interlocks visible break grounding switches automatic safety shutters and you can also go with arc resistant construction if you need it.All the live parts are enclosed and with the draw out breaker you can actually see the air gap when it is in the test position which gives you that extra peace of mind when doing maintenance.
Hot Tags: 15kv meta-clad switchgear, China 15kv meta-clad switchgear manufacturers, factory, XGN2 12 Switchgear, KYN61 40 5 Switchgear, Medium Voltage Air Insulated Switchgear, 35kV Switchgear, 20kV Switchgear, Flameproof Switchgear