Product Description
Dry Air Insulated Ring Main Unit is a new generation of "fluorine-free, low solid waste"green environmentally friendly circuit breaker switch and gas insulated ring main unit developed to replace traditional SF6 gas insulated equipment. It adopts a combination of environmentally friendly gas insulation and vacuum interruption, offering high overall performance by leveraging the advantages of both technologies.

Technical Parameters
|
Item |
Unit |
FN12-10 |
FZN25-12 |
|
|
Rated Voltage |
KV |
12 |
||
|
1min Power Frequency Withstand Voltage |
42(phase-to-phase and phase-to-ground);48(across the isolating distance) |
|||
|
Lightning Impulse Withstand Voltage(peak) |
75(phase-to-phase and phase-to-ground);85(across the isolating distance) |
|||
|
Rated Frequency |
HZ |
50 |
||
|
Rated Current of Main Busbar |
A |
630 |
||
|
Load Switch |
Rated Current |
630 |
||
|
Electrical Endurance at Rated Current |
Times |
not less than 100 |
||
|
Breaking Capacity of No-Load Transformer |
KVA |
1250 |
||
|
Rated Short-time Withstand Current(RMS) |
KA/s |
20/4; Earthing switch 20/2 |
||
|
Rated Dynamic(Peak) Withstand Current |
KA |
50 |
||
|
Rated Short-circuit Making Current(peak) |
50 |
|||
|
Rated Current of Fuse |
KV |
100 |
||
|
Rated Transfer Current |
1500 |
2000 |
||
|
Rated Short-circuit Breaking Current |
KA |
315 |
||
|
Model of Matching Fuse |
SLAJ-12(XRNT-10) |
|||
|
Mechanical Life |
Times |
2000 |
10000 |
|
|
1min Power Frequency Withstand Voltage of Auxiliary Circuit |
KV |
2 |
||
|
Operating Voltage of Electric Operating Mechanism |
V |
AC/DC 220; 110 |
||
|
Protection Grade |
IP2X |
|||
|
Dimensions(Width*Depth*Height) |
mm |
650(850)*900*2000(2200) |
||
Advantages
It uses dry compressed air instead of SF6 gas,so there are zero greenhouse gas emissions,which meets today's environmental standards without compromising performance.
The vacuum interrupter handles arc extinguishing reliably,and the high mechanical life design stands up to the constant switching demands of industrial loads.
It is rated at 12kV,630A main bus,and 20kA for 4 seconds short time withstand.Reserved automation interfaces make it easy to connect to distribution automation systems when you are ready to upgrade.
Applications
- Urban distribution network
- Industrial park
- Commercial complex
- Rail transit
Frequently Asked Questions
Q1: What is the main advantage of using dry air instead of SF6 gas in ring main units?
A: The main advantage is environmental sustainability.SF6 gas has a global warming potential that is 23,500 times higher than CO₂,so it is a pretty big deal.By using dry compressed air as the insulating medium,this Dry Air Insulated Ring Main Unit gets you zero greenhouse gas emissions while still keeping things compact and reliable.It also means you do not have to deal with SF6 handling,monitoring,or recycling,which cuts down on long term operational costs.
Q2: How does the unit perform under earthquake conditions?
A: It is designed to withstand earthquake intensity up to magnitude 8.The mechanical structure is robust and the mounting is secure,so it keeps running or shuts down safely during seismic events.That makes it a good option for installation in seismically active regions.
Q3: What protection grade does the unit have,and is it suitable for outdoor installation?
A: The standard protection grade is IP2X,which gives you protection against solid objects larger than 12.5 millimeters but does not handle water.So it is really designed for indoor installation.If you need to put it outdoors,you will have to install it inside a weatherproof enclosure that meets at least IP54 rating to keep rain and dust out.
Hot Tags: dry air insulated ring main unit, China dry air insulated ring main unit manufacturers, factory, outdoor prefabricated enclosed ring main unit, Fully Insulated SF6 Ring Main Unit, Non Metal Enclosed RMC Box, Solid Insulated Ring Main Unit, Dry Air Insulated Ring Main Unit, Metal Enclosed RMC Box