Product Description
This KYN28-12 switchgear is made from high quality aluminum zinc coated steel plate, so the build is solid. Operation is flexible, parts are easy to swap out,and it is stable, safe, and pretty intelligent too. You can pair it with either domestic or imported breakers, which gives you some flexibility. As for where it is used, think power plants, substations, distribution rooms, and all kinds of industrial, commercial, and building applications. And it meets IEC62271-200, GB/T3906, GB/T11022, and DL/T404 standards, so it checks all the necessary boxes.

Technical Parameters
|
Item |
Unit |
Data |
|
|
Rated Voltage |
kV |
3.6,7.2,12 |
|
|
Rated Frequency |
Hz |
50 |
|
|
Rated Current of Circuit Breaker |
A |
630,1250,1600,2000,2500,3150 |
|
|
Rated Current of Switchgear |
A |
630,1250,1600,2000,2500,3150 |
|
|
Rated Short-time Withstand Current(4s) |
kA |
20,25,31.5,40 |
|
|
Rated Peak Withstand Current(peak) |
kA |
50,63,80,100 |
|
|
Rated Short-circuit Breaking Current |
kA |
20,25,31.5,40 |
|
|
Rated Short-circuit Making Current(peak) |
kA |
50,63,80,100 |
|
|
Rated Insulation Level 1min Power Frequency Withstand Voltage |
Between poles and between pole and earth |
kV |
24,32,42 |
|
Lightning Impulse Withstand Voltage(peak) |
Between poles and between pole and earth |
kV |
40,60,75 |
|
Protection Level |
Enclosure:IP4X;Between compartments and when breaker door open:IP2X |
||
Overall Dimensions(mm)
|
Height |
2300 |
|
Width for Rated Current 1250A and below |
800 |
|
Width for Rated Current 1600A and above |
1000 |
|
Depth for Cable Incoming/Outgoing |
1500 |
|
Depth for Overhead Incoming/Outgoing |
1660 |
Advantages
Entirely metal armored,assembly structure,wide range of assembly schemes.
It can assembly home produced VS1 series or the imported VD4 series vacuum circuit breakers,with wide applicability,high reliability,free of maintenance for long years.
Operation and testing positions will be established for the handcart,and both positions are equipped with safe and reliable positioning device and display device.
All kinds of handcarts shall change in a modules cordwood manner,so as ensure that handcarts of same kind can be freely exchanged,while carts of different kinds are stricktly stopped from entering.
Applications
Power plants
Industrial facilities
Infrastructure
Commercial Buildings
Utility and secondary substations
Frequently Asked Questions
Q1: What does KYN28-12 Switchgear stand for?
A: So the letters and numbers each mean something.K stands for armoured,which in this case means metal clad.Y means withdrawable,so the breaker pulls out.N is for indoor use.The 28 is just the design serial number,and the 12 is the rated voltage,so 12kV.
Q2: What are the standard current ratings?
A: You have a good range to pick from,630 amps,800,1250,1600,2000,2500,3150,and up to 4000 amps.One thing to note,the 3150 amp version runs on natural cooling only,no forced cooling needed.
Q3: What is the BIL rating for 12kV class?
A: For the 12kV class,the lightning impulse withstand voltage comes in at 75 kV peak.
Hot Tags: kyn28-12 switchgear, China kyn28-12 switchgear manufacturers, factory, XGN2 12 Switchgear, KYN61 40 5 Switchgear, Medium Voltage Air Insulated Switchgear, 35kV Switchgear, 20kV Switchgear, Flameproof Switchgear